Browse Technologies

Displaying 11 - 20 of 49


Model-based Compression Correction Framework for Ultrasound

Vanderbilt researchers have developed a system that corrects for compressional effects in ultrasound data during soft tissue imaging. The system uses tracking and digitization information to detect the pose of the ultrasound probe during imaging, and then couples this information with a biomechanical model of the tissue to correct compressional effects during intraoperative imaging.


Licensing Contact

Philip Swaney

615.322.1067

System and Methods for Contact Detection and Localization in Continuum Robots

This technology expands the capabilities of continuum robots with a system and method that enables them to detect instances of contact and to estimate the position of the contact. This framework allows the motion of the robot to be constrained so as to ensure the robot doesn't damage itself, another robot arm, or surrounding environments. Applications for this technology include enhanced safe telemanipulation for multi-arm continuum robots in surgery, micro-assembly in confined spaces, and exploration in unknown environments.


Licensing Contact

Masood Machingal

615.343.3548

TagDock: An Efficient Rigid Body Molecular Docking Algorithm For Three Dimensional Models of Oligomeric Biomolecular Complexes With Limited Experimental Restraint Data

TagDock is an efficient rigid body molecular docking algorithm that generates three-dimensional models of oligomeric biomolecular complexes in instances where there is limited experimental restraint data to guide the docking calculations. Through "distance difference analysis" TagDock additionally recommends followup experiments to further discriminate divergent (score-degenerate) clusters of TagDock's initial solution models


Licensing Contact

Masood Machingal

615.343.3548

Diagnostics Management Team

The sheer volume of medical information available to physicians today is overwhelming. Diagnostic Management Team provides a concise, accurate method for ordering the correct diagnostic tests every time, and it returns the results in a uniform report format, easily read by the physician. This has already been launched within Vanderbilt University, with a high adoption rate amongst physicians and has already shown significant savings.


Licensing Contact

Chris Harris

615.343.4433

Inventors

Mary Zutter
Oncology

One-Step Hydrosilylation for Click Chemistry Compatible Surfaces

Vanderbilt inventors have developed a one-step hydrosilylation synthesis of azide surfaces for the preparation of click chemistry compatible substrates. In this process, an organic azide is formed in a single step on a hydrogen-terminated silicon support, yielding a surface that is ready to undergo click reactions as desired. Simple, efficient, and versatile, click chemistry is widely used and is particularly useful for biosensing applications. A click reaction can be utilized to attach a molecular or biological probe for point-of-care diagnostics and chemical screening.


Licensing Contact

Ashok Choudhury

615.322.2503

PIQASO: A rigid phantom for comprehensive end-to-end evaluation of online adaptive radiotherapy systems

There is currently no radiotherapy phantom capable of quantitatively assessing all components of an online adaptive radiotherapy (online ART) system in a comprehensive end-to-end test.Represented here is a novel, rigid phantom that can simultaneously evaluate an online ART system's image acquisition, deformable image registration, contour propagation, plan re-optimization, dose calculation, and beam delivery in a single process that is robust, quantitative, and convenient.


Licensing Contact

Masood Machingal

615.343.3548

Early Detection of Implant Loosening

Vanderbilt University researchers have developed a new technique for identifying implantloosening. The technique utilizes the analysis of synovial fluid as an early indicator of potential loosening of orthopedic implants.


Licensing Contact

Ashok Choudhury

615.322.2503

Nanoporous Atomically Thin Breathable Personal Protective Membranes

Vanderbilt researchers have developed an atomically thin membrane with extremely high selectivity and permeability for use in personal protective equipment.


Licensing Contact

Philip Swaney

615.322.1067

Nanoporous Atomically Thin Graphene Membranes for Desalination & Nanofiltration

Vanderbilt researchers have developed an atomically thin membrane with extremely high selectivity and permeability for use in desalination and nanofiltration applications.


Licensing Contact

Philip Swaney

615.322.1067

A Novel Organs-On-Chip Platform

Vanderbilt researchers have created a new multi-organs-on-chip platform that comprises Perfusion Control systems, MicroFormulators, and MicroClinical Analyzers connected via fluidic networks. The real-time combination of multiple different solutions to create customized perfusion media and the analysis of the effluents from each well are both controlled by the intelligent use of a computer-operated system of pumps and valves. This permits, for the first time, a compact, low-cost system for creating a time-dependent drug dosage profile in a tissue system inside each well.


Licensing Contact

Ashok Choudhury

615.322.2503